Products

You are here: Home » Products » MIS(Minimally Invasive Surgery) » Surgical Stapler » Endoscopic » Powered Yitian » YiTian II Disposable Endoscopic Stapler

loading

YiTian II Disposable Endoscopic Stapler

This stapler is designed for tissue transection,resection and anatomosis of endosopic surgery
  • YiTian

  • WASTON

  • HSD-S/HSD-B/HSD-L

  • Ti

  • HSD-S/HSD-B/HSD-L

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

1.WASTON YiTian II Disposable Endoscopic Stapler specification 


Stapler



Code Description
HSD-S Articulating Endoscopic Linear Cutter * 277mm Short
HSD-B Articulating Endoscopic Linear Cutter * 377mm Standard
HSD-L Articulating Endoscopic Linear Cutter * 477mm Extra-long



Reloads


Code Color Suture length Cutting length Staple height Trocar
HSZ-30-WT(R) White 30 25 2.0/2.5/3.0 12
HSZ-45-WT(R) 45 40
HSZ-60-WT(R) 60 55
HSZ-30-PT(R) Purple 30 25 3.0/3.5/4.0
HSZ-45-PT(R) 45 40
HSZ-60-PT(R) 60 55
HSZ-45-BT(R) Black 45 40 4.0/4.5/5.0 15
HSZ-60-BT(R) 60 55
HSZ-45-W(R) White 45 40 2.5 12
HSZ-60-W(R) 60 55
HSZ-45-B(R) Blue 45 40 3.5
HSZ-60-B(R) 60 55
HSZ-45-D(R) Gold 45 40 4
HSZ-60-D(R) 60 55
HSZ-45-G(R) Green 45 40 4.8 15
HSZ-60-G(R) 60 55


2.WASTON YiTian II Disposable Endoscopic Stapler Feature


The YiTian Disposable Endoscopic Stapler is a surgical instrument used in minimally invasive procedures, particularly for laparoscopic and thoracoscopic surgeries. It is designed to create secure and reliable tissue closure by stapling and cutting simultaneously.


Key Features:


Ergonomic Design – Provides a comfortable grip for precise control and maneuverability.

360° Rotatable Articulating Head – Allows for better access to difficult surgical sites and enhanced flexibility during procedures.

Multiple Staple Heights – Available with different cartridge sizes to accommodate various tissue thicknesses.

Precise Staple Formation – Ensures uniform and secure stapling to reduce the risk of bleeding and leakage.

Integrated Cutting Mechanism – Cuts tissue while stapling, reducing operative time.

Single-Use Disposable Design – Ensures sterility and prevents cross-contamination.

Low Firing Force – Reduces hand fatigue for surgeons, making long procedures more efficient.

Safety Lock Mechanism – Prevents accidental firing and enhances operational safety.

Wide Surgical Applications:

  • Thoracic surgery (e.g., lung resections)

  • Gastrointestinal surgery (e.g., gastric bypass, colorectal surgery)

  • Bariatric surgery

  • Gynecological procedures


3.WASTON YiTian II Disposable Endoscopic Stapler indication


The WASTON YiTian Disposable Endoscopic Stapler is designed for use in minimally invasive surgeries (MIS) to simultaneously staple and cut tissue. It is commonly used in laparoscopic and thoracoscopic procedures where precise tissue division and closure are required.


Primary Indications:


Thoracic Surgery

  • Lung resection (lobectomy, segmentectomy, wedge resection)

  • Pulmonary procedures requiring tissue division and stapling


Gastrointestinal Surgery

  • Gastric resections (gastrectomy, sleeve gastrectomy)

  • Bariatric surgery (gastric bypass, sleeve gastrectomy)

  • Small intestine and colon resections (colectomy, anastomosis)


Bariatric Surgery

  • Stapling in weight-loss procedures like gastric sleeve or gastric bypass


Colorectal Surgery

  • Colectomy, rectal resections, and anastomosis in colorectal cancer treatment


Gynecological Surgery

  • Resection of pelvic tissues

  • Procedures involving uterine or ovarian surgeries


Endocrine Surgery

  • Partial removal of tissues in minimally invasive thyroid or adrenal surgeries


Contraindications:

❌ Not for use in tissues that cannot withstand stapling
❌ Avoid in highly infected or necrotic tissues
❌ Not recommended for vascular suturing


4.WASTON YiTian Disposable Endoscopic Stapler Download


waston stapler.pdf



5.WASTON Video



6.Waston Factory Show


WPS拼图123



7. WASTON YiTian II Disposable Endoscopic Stapler FAQ


1. What is the WASTON YiTian Disposable Endoscopic Stapler?

The WASTON YiTian Disposable Endoscopic Stapler is a single-use surgical instrument designed for minimally invasive procedures. It is used to simultaneously staple and cut tissue, ensuring secure closure in thoracic, gastrointestinal, bariatric, and gynecological surgeries.


2. What are the main features of the stapler?

  • 360° Rotating & Articulating Head for better surgical access

  • Precise Staple Formation for secure tissue closure

  • Low Firing Force reduces hand fatigue

  • Multiple Staple Heights for different tissue thicknesses

  • Integrated Cutting Mechanism for efficient tissue division

  • Single-Use Design to prevent cross-contamination


3. What surgical procedures is it used for?

It is commonly used in:
Thoracic Surgery (Lobectomy, Wedge Resection)
Gastrointestinal Surgery (Gastrectomy, Colectomy)
Bariatric Surgery (Gastric Sleeve, Gastric Bypass)
Gynecological Surgery
Colorectal Surgery


4. What staple sizes are available?

The stapler is compatible with different cartridge sizes to accommodate various tissue thicknesses. Available staple heights include:
2.5mm, 3.5mm, 4.8mm – Suitable for thin to thick tissues


5. Is the WASTON YiTian Stapler reusable?

No, it is a single-use disposable device to maintain sterility and reduce infection risks.


6. Does it have a safety mechanism?

Yes, the stapler includes a safety lock mechanism to prevent accidental firing and ensure precise operation.


7. How is the stapler operated?

It is designed for one-hand operation, providing ease of use for surgeons. The stapler fires and cuts tissue simultaneously for efficient surgical procedures.


8. Can it be used for vascular surgery?

No, the stapler is not intended for vascular applications. It is designed for soft tissue stapling in general and minimally invasive surgery.


9. What are the contraindications?

  • Not for use in highly infected or necrotic tissues

  • Not suitable for vascular anastomosis

  • Avoid use in tissues too thick or too thin for the selected staple size


10. How is the stapler disposed of after use?

As a single-use medical device, it should be disposed of according to hospital biohazard waste protocols.




Previous: 
Next: 

Product Category

Contact Us

Your Expert surgical medical 
instruments Supplier
Claire  claire.zhang@waston-global.com
 
Discover more about waston group,please visit 
www.waston-global.com
Adhering to ideas of cooperation
www.waston-global.com
Waston has been emphasizing collaboration with clinical experts.
Adhering to ideas of cooperation
Home

Solution

Discover

Follow Us

© COPYRIGHT 2024 WASTON ALL RIGHTS RESERVED.